title: "ADA Sign Requirements Checker: Free Tool for Sign Makers"
description: "Enter a sign's letter height, stroke, spacing, braille and mounting height and see which 2010 ADA §703 rules it meets. Free, in inches or millimetres."
url: "https://www.signcustomiser.com/resources/ada-sign-checker/"
last_updated: "2026-11-20"
---

## How to read your result

Each line is one rule from §703 of the 2010 ADA Standards for Accessible Design, with its section number, so you can look it up or quote it back to a customer. **Meets** means the number you entered is inside the limit. **Fails** means it is outside, and the line says by how much. **Not checked** means a field is empty or two numbers disagree, so the checker has nothing to judge. It never counts a missing measurement as a pass.

Measure the way the standard does. Letter height is the uppercase I, from its baseline to its top. Stroke width is the width of that I. Letter spacing is the narrowest gap between two neighbouring letters, not counting word spaces. Mounting heights run from the finished floor to a baseline, not to the edge of the plate.

Pick **Room sign** for anything that names a permanent room or space: restrooms, room numbers, stair and exit doors. Pick **Directional or overhead sign** for signs that point the way or give information, which need the visual rules only.

## The rules the checker applies

We read §703 and §216 on ada.gov and the US Access Board's guide to signs on 20 November 2026. Inch values come first; in millimetre mode the checker uses the metric values printed in the standard itself.

Rule

Raised (tactile) letters

Visual letters

Letter height (uppercase I)

5/8 in (16 mm) to 2 in (51 mm); 1/2 in (13 mm) if a separate visual sign repeats the words

By Table 703.5.5, below

Case

Capitals only

Capitals, lower case or both

Style

Sans serif; no italic, oblique, script or decorative

Conventional; no italic, oblique, script or decorative

Width of O

55% to 110% of the I height

55% to 110% of the I height

Stroke of I

15% of the height at most

10% to 30% of the height

Letter spacing

1/8 in (3.2 mm) minimum, 4 strokes maximum

10% to 35% of the height

Line spacing

135% to 170% of the height

135% to 170% of the height

Raised depth

1/32 in (0.8 mm) minimum

–

Braille

Grade 2, below the words, 3/8 in (9.5 mm) clear of them

–

Mounting

Lowest tactile baseline 48 in (1220 mm) or more; top baseline 60 in (1525 mm) or less

40 in (1015 mm) or more

Finish and contrast

Non-glare, light on dark or dark on light (not needed if a separate visual sign repeats the words)

Non-glare, light on dark or dark on light

### Visual letter height (Table 703.5.5)

Baseline above the floor

Viewing distance

Minimum letter I

40 to 70 in

under 72 in (6 ft)

5/8 in

40 to 70 in

72 in or more

5/8 in, plus 1/8 in per foot beyond 6 ft

over 70 in to 120 in

under 180 in (15 ft)

2 in

over 70 in to 120 in

180 in or more

2 in, plus 1/8 in per foot beyond 15 ft

over 120 in

under 21 ft

3 in

over 120 in

21 ft or more

3 in, plus 1/8 in per foot beyond 21 ft

Viewing distance is the horizontal distance from the letters to the nearest thing that stops a reader walking closer, such as a counter or a rail. The checker adds the 1/8 inch for part feet in proportion.

### What it does not check

The checker judges numbers, not artwork. It cannot read your wording, confirm that the braille is a correct Grade 2 translation, measure braille dots, see where the sign sits at the door (the latch side, with an 18 by 18 inch clear floor space beyond the door swing) or apply state and local codes, which can ask for more. On letters with rounded or bevelled edges it checks the spacing at the top of the letters only; at the base the minimum is 1/16 in (1.6 mm). Elevator signs and controls have their own exceptions and are out of scope. The result is a check of the measurements you entered, not legal advice.

## Worked example: a room sign proof

A customer sends a drawing for a conference room sign: the room name in 1/2 inch script lettering in upper and lower case, Grade 1 braille under it, and the plate placed so the top line sits at 61 inches. The checker returns 7 failures:

- **Raised letter height** (§703.2.5): 0.5 in against 5/8 in (16 mm) to 2 in (51 mm).
- **Capitals only** (§703.2.2): Raised letters must be capitals; lower case is allowed only on visual characters.
- **Sans serif style** (§703.2.3): Italic, oblique, script and decorative letters are not allowed.
- **Stroke thickness** (§703.2.6): The I stroke is 20% of the letter height; the rule is 15% at most.
- **Letter proportions** (§703.2.4): The O is 120% of the I height; the rule is 55% to 110%.
- **Grade 2 braille** (§703.3): Uncontracted (Grade 1) braille does not meet §703.3, which asks for contracted (Grade 2).
- **Highest tactile line** (§703.4.1): 61 in from the floor to the baseline of the top line, against 60 in (1525 mm) maximum.

1. Step 1

    ### Fix the lettering

    Switch to plain sans serif capitals with the I at 3/4 inch. A 0.1 inch stroke is 13% of that, under the 15% limit, and an O 0.6 inch wide is 80% of the I height.

2. Step 2

    ### Fix the braille

    Translate the words to contracted Grade 2 braille and set it 3/8 inch below the raised words.

3. Step 3

    ### Fix the mounting height

    Lower the plate so the braille baseline is at 48.5 inches and the top line's baseline at 49.75 inches.

The revised sign meets 13 of 13 checks, with nothing left unchecked. That is the checker's starting example, so you can open it above and change one number at a time.

### An overhead sign

A directional sign hangs with its letter baseline at 84 inches, and the closest a visitor can stand is 20 feet away. That falls in the second row of the table: 2 inches, plus 1/8 inch for each of the 5 feet beyond 15 feet, so the letter I must be at least 2.625 in tall.

For sign businesses

## Sell ADA braille signs online

Catch ADA problems before a customer's drawing reaches the router. With [Sign Customiser's Braille signs](/solutions/braille-signs/), customers type the room name on your website and see the braille row appear under it, with the plate size and price. Stores that sell in USD default to contracted Grade 2 braille and ADA dot geometry, and add to cart stays blocked until the current wording has translated. Each order reaches you with the wording, the braille string, the table, the grade and the dot geometry, and the SVG file, once you turn it on, places every dot as an exact vector circle. You still check the finished sign; the checker above is how you do it in a minute.

[Start your free 7-day trial](/install/)

## Related tools and guides

[Braille signsSell ADA braille signs online with braille translated as customers type.](/solutions/braille-signs/)[Sign letter height calculatorLetter height for any viewing distance or traffic speed.](/resources/sign-letter-height-calculator/)[Sign cost calculatorPrice a sign from your materials, labour and target margin.](/resources/sign-cost-calculator/)[Sign proof approvalGet a customer's sign-off on size and wording before you make it.](/posts/general/sign-proof-approval/)[All free sign toolsMakers, generators and calculators for designing and pricing signs.](/resources/)

## Frequently asked questions

What are the ADA requirements for signs?

Section 703 of the 2010 ADA Standards sets them. Signs that name a permanent room or space need raised capital letters 5/8 in (16 mm) to 2 in (51 mm) tall in a plain sans serif, repeated in Grade 2 braille, mounted with their baselines 48 in (1220 mm) to 60 in (1525 mm) above the floor, with a non-glare finish and strong contrast. Directional and informational signs need only the visual rules, where the letter height depends on how high the sign is and how close a reader can get.

How high do ADA signs need to be mounted?

Tactile signs: the baseline of the lowest tactile line (usually the braille) at 48 in (1220 mm) or more above the floor, and the baseline of the top line of raised letters at 60 in (1525 mm) or less. At a door the sign goes on the latch side. Visual characters must be at least 40 in (1015 mm) above the floor.

Which signs need braille?

Interior and exterior signs that identify permanent rooms and spaces, such as restroom, room number and stair signs (§216.2). Directional and informational signs need visual characters only (§216.3). Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos are exempt from §216.

How big must ADA sign letters be?

Raised letters: 5/8 in (16 mm) to 2 in (51 mm), measured on the uppercase I, or 1/2 in (13 mm) minimum when the same words are also on a separate visual sign. Visual letters: from 5/8 in at eye level and close range up to 3 in or more on high signs read from far away, by Table 703.5.5. The checker works out the visual minimum for you.

Can ADA tactile letters be lower case?

No. Raised characters must be uppercase (§703.2.2). Visual characters on a separate sign can be uppercase, lowercase or both (§703.5.2).

Is there an ADA-approved font?

No font is named. The standard sets rules any font must meet: sans serif and not italic, script or decorative for raised letters; an O between 55% and 110% as wide as the I is tall; and an I stroke no thicker than 15% of the letter height (10% to 30% for visual letters). Measure your chosen font against those numbers.

Sources: 2010 ADA Standards for Accessible Design, §216 and §703 (ada.gov); US Access Board, _Guide to the ADA Accessibility Standards_, Chapter 7: Signs. Read on 20 November 2026.

Cite this tool: Sign Customiser, “ADA sign requirements checker”, https://www.signcustomiser.com/resources/ada-sign-checker/

## Sitemap

See the full [sitemap](/sitemap.md) for all pages.