Free tool
ADA sign requirements checkerfor room and directional signs
Result
13 of 13 checks met
13 met, 0 failed, 0 not checked. Empty fields are not checked.
- Raised letter height §703.2.5Meets
0.75 in against 5/8 in (16 mm) to 2 in (51 mm).
- Capitals only §703.2.2Meets
Raised letters are all capitals.
- Sans serif style §703.2.3Meets
Plain sans serif letters.
- Stroke thickness §703.2.6Meets
The I stroke is 13.3% of the letter height; the rule is 15% at most.
- Letter proportions §703.2.4Meets
The O is 80% of the I height; the rule is 55% to 110%.
- Raised depth §703.2.1Meets
0.031 in against 1/32 in (0.8 mm) minimum.
- Letter spacing §703.2.7Meets
0.15 in against 1/8 in (3.2 mm) minimum and 0.4 in (4 strokes) maximum.
- Grade 2 braille §703.3Meets
Contracted (Grade 2) braille repeats the raised words.
- Braille below the words §703.3.2Meets
0.375 in between the raised words and the braille below them, against 3/8 in (9.5 mm) minimum.
- Lowest tactile line §703.4.1Meets
48.5 in from the floor to the baseline of the lowest tactile line (usually the braille), against 48 in (1220 mm) minimum.
- Highest tactile line §703.4.1Meets
49.75 in from the floor to the baseline of the top line, against 60 in (1525 mm) maximum.
- Non-glare finish §703.5.1Meets
Letters and background have a non-glare finish.
- Contrast §703.5.1Meets
Light letters on a dark background, or dark on light.
This checks the measurements you entered against §703 of the 2010 ADA Standards. It is not legal advice, and it does not check the wording, the braille translation, the sign's location at the door or local building codes.
How to readyour result
Each line is one rule from §703 of the 2010 ADA Standards for Accessible Design, with its section number, so you can look it up or quote it back to a customer. Meets means the number you entered is inside the limit. Fails means it is outside, and the line says by how much. Not checked means a field is empty or two numbers disagree, so the checker has nothing to judge. It never counts a missing measurement as a pass.
Measure the way the standard does. Letter height is the uppercase I, from its baseline to its top. Stroke width is the width of that I. Letter spacing is the narrowest gap between two neighbouring letters, not counting word spaces. Mounting heights run from the finished floor to a baseline, not to the edge of the plate.
Pick Room sign for anything that names a permanent room or space: restrooms, room numbers, stair and exit doors. Pick Directional or overhead sign for signs that point the way or give information, which need the visual rules only.
The rulesthe checker applies
We read §703 and §216 on ada.gov and the US Access Board's guide to signs on 20 November 2026. Inch values come first; in millimetre mode the checker uses the metric values printed in the standard itself.
| Rule | Raised (tactile) letters | Visual letters |
|---|---|---|
| Letter height (uppercase I) | 5/8 in (16 mm) to 2 in (51 mm); 1/2 in (13 mm) if a separate visual sign repeats the words | By Table 703.5.5, below |
| Case | Capitals only | Capitals, lower case or both |
| Style | Sans serif; no italic, oblique, script or decorative | Conventional; no italic, oblique, script or decorative |
| Width of O | 55% to 110% of the I height | 55% to 110% of the I height |
| Stroke of I | 15% of the height at most | 10% to 30% of the height |
| Letter spacing | 1/8 in (3.2 mm) minimum, 4 strokes maximum | 10% to 35% of the height |
| Line spacing | 135% to 170% of the height | 135% to 170% of the height |
| Raised depth | 1/32 in (0.8 mm) minimum | – |
| Braille | Grade 2, below the words, 3/8 in (9.5 mm) clear of them | – |
| Mounting | Lowest tactile baseline 48 in (1220 mm) or more; top baseline 60 in (1525 mm) or less | 40 in (1015 mm) or more |
| Finish and contrast | Non-glare, light on dark or dark on light (not needed if a separate visual sign repeats the words) | Non-glare, light on dark or dark on light |
Visual letter height (Table 703.5.5)
| Baseline above the floor | Viewing distance | Minimum letter I |
|---|---|---|
| 40 to 70 in | under 72 in (6 ft) | 5/8 in |
| 40 to 70 in | 72 in or more | 5/8 in, plus 1/8 in per foot beyond 6 ft |
| over 70 in to 120 in | under 180 in (15 ft) | 2 in |
| over 70 in to 120 in | 180 in or more | 2 in, plus 1/8 in per foot beyond 15 ft |
| over 120 in | under 21 ft | 3 in |
| over 120 in | 21 ft or more | 3 in, plus 1/8 in per foot beyond 21 ft |
Viewing distance is the horizontal distance from the letters to the nearest thing that stops a reader walking closer, such as a counter or a rail. The checker adds the 1/8 inch for part feet in proportion.
What it does not check
The checker judges numbers, not artwork. It cannot read your wording, confirm that the braille is a correct Grade 2 translation, measure braille dots, see where the sign sits at the door (the latch side, with an 18 by 18 inch clear floor space beyond the door swing) or apply state and local codes, which can ask for more. On letters with rounded or bevelled edges it checks the spacing at the top of the letters only; at the base the minimum is 1/16 in (1.6 mm). Elevator signs and controls have their own exceptions and are out of scope. The result is a check of the measurements you entered, not legal advice.
Worked example:a room sign proof
A customer sends a drawing for a conference room sign: the room name in 1/2 inch script lettering in upper and lower case, Grade 1 braille under it, and the plate placed so the top line sits at 61 inches. The checker returns 7 failures:
- Raised letter height (§703.2.5): 0.5 in against 5/8 in (16 mm) to 2 in (51 mm).
- Capitals only (§703.2.2): Raised letters must be capitals; lower case is allowed only on visual characters.
- Sans serif style (§703.2.3): Italic, oblique, script and decorative letters are not allowed.
- Stroke thickness (§703.2.6): The I stroke is 20% of the letter height; the rule is 15% at most.
- Letter proportions (§703.2.4): The O is 120% of the I height; the rule is 55% to 110%.
- Grade 2 braille (§703.3): Uncontracted (Grade 1) braille does not meet §703.3, which asks for contracted (Grade 2).
- Highest tactile line (§703.4.1): 61 in from the floor to the baseline of the top line, against 60 in (1525 mm) maximum.
Step 1
Fix the lettering
Switch to plain sans serif capitals with the I at 3/4 inch. A 0.1 inch stroke is 13% of that, under the 15% limit, and an O 0.6 inch wide is 80% of the I height.
Step 2
Fix the braille
Translate the words to contracted Grade 2 braille and set it 3/8 inch below the raised words.
Step 3
Fix the mounting height
Lower the plate so the braille baseline is at 48.5 inches and the top line's baseline at 49.75 inches.
The revised sign meets 13 of 13 checks, with nothing left unchecked. That is the checker's starting example, so you can open it above and change one number at a time.
An overhead sign
A directional sign hangs with its letter baseline at 84 inches, and the closest a visitor can stand is 20 feet away. That falls in the second row of the table: 2 inches, plus 1/8 inch for each of the 5 feet beyond 15 feet, so the letter I must be at least 2.625 in tall.
For sign businesses
Sell ADA braille signsonline
Catch ADA problems before a customer's drawing reaches the router. With Sign Customiser's Braille signs, customers type the room name on your website and see the braille row appear under it, with the plate size and price. Stores that sell in USD default to contracted Grade 2 braille and ADA dot geometry, and add to cart stays blocked until the current wording has translated. Each order reaches you with the wording, the braille string, the table, the grade and the dot geometry, and the SVG file, once you turn it on, places every dot as an exact vector circle. You still check the finished sign; the checker above is how you do it in a minute.
Relatedtools and guides
Frequently askedquestions
What are the ADA requirements for signs?
Section 703 of the 2010 ADA Standards sets them. Signs that name a permanent room or space need raised capital letters 5/8 in (16 mm) to 2 in (51 mm) tall in a plain sans serif, repeated in Grade 2 braille, mounted with their baselines 48 in (1220 mm) to 60 in (1525 mm) above the floor, with a non-glare finish and strong contrast. Directional and informational signs need only the visual rules, where the letter height depends on how high the sign is and how close a reader can get.
How high do ADA signs need to be mounted?
Tactile signs: the baseline of the lowest tactile line (usually the braille) at 48 in (1220 mm) or more above the floor, and the baseline of the top line of raised letters at 60 in (1525 mm) or less. At a door the sign goes on the latch side. Visual characters must be at least 40 in (1015 mm) above the floor.
Which signs need braille?
Interior and exterior signs that identify permanent rooms and spaces, such as restroom, room number and stair signs (§216.2). Directional and informational signs need visual characters only (§216.3). Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos are exempt from §216.
How big must ADA sign letters be?
Raised letters: 5/8 in (16 mm) to 2 in (51 mm), measured on the uppercase I, or 1/2 in (13 mm) minimum when the same words are also on a separate visual sign. Visual letters: from 5/8 in at eye level and close range up to 3 in or more on high signs read from far away, by Table 703.5.5. The checker works out the visual minimum for you.
Can ADA tactile letters be lower case?
No. Raised characters must be uppercase (§703.2.2). Visual characters on a separate sign can be uppercase, lowercase or both (§703.5.2).
Is there an ADA-approved font?
No font is named. The standard sets rules any font must meet: sans serif and not italic, script or decorative for raised letters; an O between 55% and 110% as wide as the I is tall; and an I stroke no thicker than 15% of the letter height (10% to 30% for visual letters). Measure your chosen font against those numbers.
Sources: 2010 ADA Standards for Accessible Design, §216 and §703 (ada.gov); US Access Board, Guide to the ADA Accessibility Standards, Chapter 7: Signs. Read on 20 November 2026.
Cite this tool: Sign Customiser, “ADA sign requirements checker”, https://www.signcustomiser.com/resources/ada-sign-checker/