NewTurn any image into a sign design.

Free tool

ADA sign requirements checkerfor room and directional signs

Enter the measurements from your drawing or proof and see, rule by rule, which ADA sign requirements it meets and which it misses, before anything goes to the router.
Which sign are you checking?
Units
in

in

in

in

in

in

in

in

Letter case
Typeface
Braille
Lines of raised words
Letter edges
Raised border or decoration
Same words on a separate visual sign?
Finish of letters and background
Contrast

Result

13 of 13 checks met

13 met, 0 failed, 0 not checked. Empty fields are not checked.

  • Raised letter height §703.2.5Meets

    0.75 in against 5/8 in (16 mm) to 2 in (51 mm).

  • Capitals only §703.2.2Meets

    Raised letters are all capitals.

  • Sans serif style §703.2.3Meets

    Plain sans serif letters.

  • Stroke thickness §703.2.6Meets

    The I stroke is 13.3% of the letter height; the rule is 15% at most.

  • Letter proportions §703.2.4Meets

    The O is 80% of the I height; the rule is 55% to 110%.

  • Raised depth §703.2.1Meets

    0.031 in against 1/32 in (0.8 mm) minimum.

  • Letter spacing §703.2.7Meets

    0.15 in against 1/8 in (3.2 mm) minimum and 0.4 in (4 strokes) maximum.

  • Grade 2 braille §703.3Meets

    Contracted (Grade 2) braille repeats the raised words.

  • Braille below the words §703.3.2Meets

    0.375 in between the raised words and the braille below them, against 3/8 in (9.5 mm) minimum.

  • Lowest tactile line §703.4.1Meets

    48.5 in from the floor to the baseline of the lowest tactile line (usually the braille), against 48 in (1220 mm) minimum.

  • Highest tactile line §703.4.1Meets

    49.75 in from the floor to the baseline of the top line, against 60 in (1525 mm) maximum.

  • Non-glare finish §703.5.1Meets

    Letters and background have a non-glare finish.

  • Contrast §703.5.1Meets

    Light letters on a dark background, or dark on light.

This checks the measurements you entered against §703 of the 2010 ADA Standards. It is not legal advice, and it does not check the wording, the braille translation, the sign's location at the door or local building codes.

How to readyour result

Each line is one rule from §703 of the 2010 ADA Standards for Accessible Design, with its section number, so you can look it up or quote it back to a customer. Meets means the number you entered is inside the limit. Fails means it is outside, and the line says by how much. Not checked means a field is empty or two numbers disagree, so the checker has nothing to judge. It never counts a missing measurement as a pass.

Measure the way the standard does. Letter height is the uppercase I, from its baseline to its top. Stroke width is the width of that I. Letter spacing is the narrowest gap between two neighbouring letters, not counting word spaces. Mounting heights run from the finished floor to a baseline, not to the edge of the plate.

Pick Room sign for anything that names a permanent room or space: restrooms, room numbers, stair and exit doors. Pick Directional or overhead sign for signs that point the way or give information, which need the visual rules only.

The rulesthe checker applies

We read §703 and §216 on ada.gov and the US Access Board's guide to signs on 20 November 2026. Inch values come first; in millimetre mode the checker uses the metric values printed in the standard itself.

RuleRaised (tactile) lettersVisual letters
Letter height (uppercase I)5/8 in (16 mm) to 2 in (51 mm); 1/2 in (13 mm) if a separate visual sign repeats the wordsBy Table 703.5.5, below
CaseCapitals onlyCapitals, lower case or both
StyleSans serif; no italic, oblique, script or decorativeConventional; no italic, oblique, script or decorative
Width of O55% to 110% of the I height55% to 110% of the I height
Stroke of I15% of the height at most10% to 30% of the height
Letter spacing1/8 in (3.2 mm) minimum, 4 strokes maximum10% to 35% of the height
Line spacing135% to 170% of the height135% to 170% of the height
Raised depth1/32 in (0.8 mm) minimum–
BrailleGrade 2, below the words, 3/8 in (9.5 mm) clear of them–
MountingLowest tactile baseline 48 in (1220 mm) or more; top baseline 60 in (1525 mm) or less40 in (1015 mm) or more
Finish and contrastNon-glare, light on dark or dark on light (not needed if a separate visual sign repeats the words)Non-glare, light on dark or dark on light

Visual letter height (Table 703.5.5)

Baseline above the floorViewing distanceMinimum letter I
40 to 70 inunder 72 in (6 ft)5/8 in
40 to 70 in72 in or more5/8 in, plus 1/8 in per foot beyond 6 ft
over 70 in to 120 inunder 180 in (15 ft)2 in
over 70 in to 120 in180 in or more2 in, plus 1/8 in per foot beyond 15 ft
over 120 inunder 21 ft3 in
over 120 in21 ft or more3 in, plus 1/8 in per foot beyond 21 ft

Viewing distance is the horizontal distance from the letters to the nearest thing that stops a reader walking closer, such as a counter or a rail. The checker adds the 1/8 inch for part feet in proportion.

What it does not check

The checker judges numbers, not artwork. It cannot read your wording, confirm that the braille is a correct Grade 2 translation, measure braille dots, see where the sign sits at the door (the latch side, with an 18 by 18 inch clear floor space beyond the door swing) or apply state and local codes, which can ask for more. On letters with rounded or bevelled edges it checks the spacing at the top of the letters only; at the base the minimum is 1/16 in (1.6 mm). Elevator signs and controls have their own exceptions and are out of scope. The result is a check of the measurements you entered, not legal advice.

Worked example:a room sign proof

A customer sends a drawing for a conference room sign: the room name in 1/2 inch script lettering in upper and lower case, Grade 1 braille under it, and the plate placed so the top line sits at 61 inches. The checker returns 7 failures:

  • Raised letter height (§703.2.5): 0.5 in against 5/8 in (16 mm) to 2 in (51 mm).
  • Capitals only (§703.2.2): Raised letters must be capitals; lower case is allowed only on visual characters.
  • Sans serif style (§703.2.3): Italic, oblique, script and decorative letters are not allowed.
  • Stroke thickness (§703.2.6): The I stroke is 20% of the letter height; the rule is 15% at most.
  • Letter proportions (§703.2.4): The O is 120% of the I height; the rule is 55% to 110%.
  • Grade 2 braille (§703.3): Uncontracted (Grade 1) braille does not meet §703.3, which asks for contracted (Grade 2).
  • Highest tactile line (§703.4.1): 61 in from the floor to the baseline of the top line, against 60 in (1525 mm) maximum.
  1. Step 1

    Fix the lettering

    Switch to plain sans serif capitals with the I at 3/4 inch. A 0.1 inch stroke is 13% of that, under the 15% limit, and an O 0.6 inch wide is 80% of the I height.

  2. Step 2

    Fix the braille

    Translate the words to contracted Grade 2 braille and set it 3/8 inch below the raised words.

  3. Step 3

    Fix the mounting height

    Lower the plate so the braille baseline is at 48.5 inches and the top line's baseline at 49.75 inches.

The revised sign meets 13 of 13 checks, with nothing left unchecked. That is the checker's starting example, so you can open it above and change one number at a time.

An overhead sign

A directional sign hangs with its letter baseline at 84 inches, and the closest a visitor can stand is 20 feet away. That falls in the second row of the table: 2 inches, plus 1/8 inch for each of the 5 feet beyond 15 feet, so the letter I must be at least 2.625 in tall.

For sign businesses

Sell ADA braille signsonline

Catch ADA problems before a customer's drawing reaches the router. With Sign Customiser's Braille signs, customers type the room name on your website and see the braille row appear under it, with the plate size and price. Stores that sell in USD default to contracted Grade 2 braille and ADA dot geometry, and add to cart stays blocked until the current wording has translated. Each order reaches you with the wording, the braille string, the table, the grade and the dot geometry, and the SVG file, once you turn it on, places every dot as an exact vector circle. You still check the finished sign; the checker above is how you do it in a minute.

Frequently askedquestions

What are the ADA requirements for signs?

Section 703 of the 2010 ADA Standards sets them. Signs that name a permanent room or space need raised capital letters 5/8 in (16 mm) to 2 in (51 mm) tall in a plain sans serif, repeated in Grade 2 braille, mounted with their baselines 48 in (1220 mm) to 60 in (1525 mm) above the floor, with a non-glare finish and strong contrast. Directional and informational signs need only the visual rules, where the letter height depends on how high the sign is and how close a reader can get.

How high do ADA signs need to be mounted?

Tactile signs: the baseline of the lowest tactile line (usually the braille) at 48 in (1220 mm) or more above the floor, and the baseline of the top line of raised letters at 60 in (1525 mm) or less. At a door the sign goes on the latch side. Visual characters must be at least 40 in (1015 mm) above the floor.

Which signs need braille?

Interior and exterior signs that identify permanent rooms and spaces, such as restroom, room number and stair signs (§216.2). Directional and informational signs need visual characters only (§216.3). Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos are exempt from §216.

How big must ADA sign letters be?

Raised letters: 5/8 in (16 mm) to 2 in (51 mm), measured on the uppercase I, or 1/2 in (13 mm) minimum when the same words are also on a separate visual sign. Visual letters: from 5/8 in at eye level and close range up to 3 in or more on high signs read from far away, by Table 703.5.5. The checker works out the visual minimum for you.

Can ADA tactile letters be lower case?

No. Raised characters must be uppercase (§703.2.2). Visual characters on a separate sign can be uppercase, lowercase or both (§703.5.2).

Is there an ADA-approved font?

No font is named. The standard sets rules any font must meet: sans serif and not italic, script or decorative for raised letters; an O between 55% and 110% as wide as the I is tall; and an I stroke no thicker than 15% of the letter height (10% to 30% for visual letters). Measure your chosen font against those numbers.

Sources: 2010 ADA Standards for Accessible Design, §216 and §703 (ada.gov); US Access Board, Guide to the ADA Accessibility Standards, Chapter 7: Signs. Read on 20 November 2026.

Cite this tool: Sign Customiser, “ADA sign requirements checker”, https://www.signcustomiser.com/resources/ada-sign-checker/